VMAX3 Solutions Specialist Exam for Implementation Engineers v7.0

Page:    1 / 5   
Exam contains 71 questions

What are the pre-configured devices used by the VMAX3 Data Services Hypervisor VM?

  • A. RDF1+TDEV
  • B. BCV+TDEV
  • C. INT+TDEV
  • D. TDEV


Answer : C

What is the status of the Host I/O paths to the target array after a Non-Disruptive Migration
Cutover?

  • A. Write Disabled
  • B. Inactive
  • C. Read/Write Enabled
  • D. Dead


Answer : B

Explanation:

Reference -
https://learningcontent.emc.com/gatekeepercontent/cninv000000000135674/presentation_ content/external_files/Non-
Disruptive%20Migration%20VMAX%20All%20Flash_VMAX3.pdf

When using TimeFinder SnapVX technology, what is the maximum number of linked targets of a snapshot that can be created?

  • A. 255
  • B. 256
  • C. 512
  • D. 1024


Answer : B

Explanation:
Reference https://www.emc.com/collateral/white-papers/h14273-vmax3-timefinder-snapvx- microsoft-sql-server.pdf (P.5)

Which feature is included with VMAX All Flash F package?

  • A. SRDF/S
  • B. Data at Rest Encryption ([email protected])
  • C. Non-Disruptive Migration (NDM)
  • D. SRDF/Metro


Answer : C

Explanation:
Reference https://www.emc.com/collateral/data-sheet/h15228-vmax-af-software-ds.pdf

Which I/O module is used by VMAX3 eNAS systems to facilitate backup to tape?

  • A. 2-port 10 GbE BaseT
  • B. 2-port 10 GbE Optical
  • C. 4-port 8 Gb FC
  • D. 4-port 16 Gb FC


Answer : C

Explanation:
Reference https://www.emc.com/collateral/technical-documentation/h13904-vmax3- embedded-nas-technical-note.pdf (page 8)

Which type of emulation is used for thin devices provisioned to an eNAS Storage Group in
VMAX3?

  • A. EMBEDDED_NAS_FBA
  • B. FBA
  • C. CELERRA_FBA
  • D. eNAS_FBA


Answer : C

What is the function of FAST hinting on a VMAX3 array?

  • A. Sends hints to the array for low access data to be compressed
  • B. Provides suggestions for manual movement of data to other tiers
  • C. Provides suggestions for data migration activities to be performed on stale data
  • D. Sends hints to the array for data that is likely to be accessed in a given period of time


Answer : D

Explanation:
Reference http://thecoreblog.emc.com/emc-world/beating-the-odds-with-fast- hinting/?cmp=soc-cor-glbl-us-sprinklr-TWITTER--EMCStorage-183819018

What is the correct sequence of actions performed by a VMAX3 when the SRDF failback command is executed?




Answer :

Explanation:



References:

From an application perspective, what should be done prior to performing an SRDF
Restore operation?

  • A. Continue accessing the R1 and R2 devices
  • B. Continue accessing the R1 devices. Stop accessing the R2 devices
  • C. Stop accessing the R1 devices. Continue accessing the R2 devices
  • D. Stop accessing the R1 and R2 devices


Answer : D

What does EMC Virtual Storage Integrator for VMware vSphere Web Client require to provision and manage storage from VMAX All Flash and VMAX3 arrays?

  • A. EMC VMAX Storage Plug-in
  • B. EMC VSS Provider
  • C. EMC Unisphere for VMAX
  • D. EMC SMI-S Provider


Answer : A

What is the minimum cycle time that can be set for SRDF/A Multi-Session Consistency?

  • A. 1 seconds
  • B. 3 seconds
  • C. 5 seconds
  • D. 15 seconds


Answer : A

Explanation:
Reference https://www.slideshare.net/DanielGarfado/emc-srdf (33)

Where is data compression enabled on a VMAX All Flash array?

  • A. Storage Group
  • B. Data Pool
  • C. Thin devices
  • D. Disk Group


Answer : A

Explanation:
Reference https://www.emc.com/collateral/white-papers/h15393-vmax-all-flash-adaptive- compression-engine.pdf (Page 4)


Based on the exhibit, a Non-Disruptive Migration (NDM) is being used to migrate a VMware datastore to a new VMAX3. Which NDM step(s) has already been completed?

  • A. NDM-Environment Setup, NDM-Create, and NDM-Cutover only
  • B. NDM-Environment Setup, NDM-Create, NDM-Cutover, and NDM Commit
  • C. NDM-Environment Setup only
  • D. NDM-Environment Setup and NDM-Create only


Answer : C

Which Database Management System(s) is used by Unisphere for VMAX v.8.3?

  • A. Oracle
  • B. PostgreSQL and MySQL
  • C. MySQL only
  • D. PostgreSQL only


Answer : D

Explanation:

Reference -
https://learningcontent.emc.com/gatekeepercontent/cninv000000000124493/presentation_ content/external_files/Unisphere%20for%20VMAX%20IM%208.3_srg.pdf (page 4)

A storage administrator wants to use the Migration Wizard in Unisphere for VMAX to create a Non-Disruptive Migration session. Where is the Migrate option located?

  • A. SID> Storage > Migrations
  • B. SID> Data Protection > SRDF
  • C. SID> Data Protection > Replication Groups and Pools
  • D. SID > Storage > Storage Groups


Answer : D

Explanation:

Reference -
https://learningcontent.emc.com/gatekeepercontent/cninv000000000135674/presentation_ content/external_files/Non-
Disruptive%20Migration%20VMAX%20All%20Flash_VMAX3.pdf (p.26)